Haibo BayGansuSurprise for customers
release time:2024-07-10 20:27:54

Advantages of electric elevator rotary valve: Simplify the installation of electric elevator pipelines; The operation is more convenient, and the valve can be opened and closed at any time; The installation of a rotary valve reduces the friction of the sealing components; Compact structure, small size and space saving; Increased the service life of electric elevator pipelines and solved the problem of easy oil leakage.Setting requirements: When the distance between the outer edge of the construction electric elevator and the external overhead power line cannot meet the requirements of a small safety distance,Correct use can also greatly improve work efficiency. So how should it be used?The wall bracket of the construction electric elevator should be intact and reliably fixed, and its attachment distance, wall bracket spacing, and end height must comply with the requirements of the 'User Manual'. The angle between the plane of the wall bracket and the normal direction of the attachment surface should not exceed degrees;. When the attachment device does not meet the requirements of the 'User Manual' due to conditions, its calculation sheet, design, and production materials should be confirmed by the manufacturer or reviewed by the technical leader of the installation unit, and verified by experts.Clement Ferrand,During loading and unloading, the horizontal distance between the edge of the cage door and the edge of the landing station should not exceed mm.Construction electric elevators outside the lightning protection rangeWhen applying a normal force of N to any position on either side of the door using a rigid mm square or circular flat surface in the locked position of the landing door,Haibo BayDetroit, the door should be able to withstand and have no deformation; - Deformation not exceeding mm; After the test, it worked normally.


Haibo BayGansuSurprise for customers



The bearing capacity of the ground under the concrete foundation plate should be greater than .Mpa.The shutdown device (emergency stop switch) should be non automatic reset type.Setting requirements: For construction electric elevators with foundations installed on roof slabs, floors, the bearing capacity of the foundation support structure should be checked. Click here to download the construction technical information for free. Basic drainage facilities should be installed.Production department,Protective measures should comply with regulatory requirements.The L distance depends on the selected wall mount model.The oil cylinder and sealing components are made of imported components to solve the problem of unstable oil pressure and oil leakage of components for customers.


Haibo BayGansuSurprise for customers



When the landing door is closed, the full width of the lifting passage opening should be covered.Quality inspection report,To meet the needs of stage craftsmanship and layout; Product; In the music and dance theater stage arranged in a zigzag pattern, auxiliary lifting platforms are often arranged in front, back, left, and right of the main stage lifting platform. The side and rear auxiliary lifting platforms are used for the smooth opening of the side platform and rear vehicle turntable, while the front auxiliary lifting platform is used to place the rear vehicle turntable near the platform entrance. The leveling and lifting platform below the side platform and rear vehicle turntable can be used to level the platform after the side platform or rear vehicle turntable is driven out, so that the entire platform does not have a height difference ensuring the safety of the cast members.Steel wire rope construction electric elevators and reusable steel wire ropes should be equipped with anti loosening rope devices, which should have compliant loosening rope switches and be able to interrupt any movement of the lifting cage until it is approved by a professionalDuring the use period,Haibo BayNew York, the user unit should organize professional technical personnel to inspect the construction electric elevator monthly according to the standard requirements, and record the inspection results.Haibo Bay,The quality of the standard section should comply with the product manual and specification requirements.Setting requirements: The foundation and foundation of the construction electric elevator should meet the requirements of the user manual. Before installing the construction electric elevator, the foundation should be inspected and accepted according to the requirements of the specifications. Only after passing the inspection can the installation be carried out.The safety notice board for construction electric elevators should be prominently placed on the hanging cage for the rated load capacity and rated number of passengers of the construction electric elevator. It is strictly prohibited to use construction electric elevators beyond the rated load capacity or rated number of passengers.


comment list
©2009-2024Industrial Microblog  Sitemap