BabrookProfessional installation cold storage installationDetailed interpretation
release time:2023-01-28 00:57:57

The refrigeration of cold storage pays more and more attention to the needs of environmental protection and energy saving. Professional projects include: cold storage installation, installation of cold storage, cold storage construction, fruit fresh-keeping cold storage medical cold storage and other related businesses. Merchants who hope to have this business please consider the wide scale of warehouse temperature control, the selection and placement of cooling equipment and the description of wind speed field, which are suitable for the cold storage needs of a variety of goods. Equipped with perfect storage temperature active detection, recording and active control equipment.Indirect cooling is that the air in the warehouse is pumped into the air cooling device by the blower. The air is absorbed by the evaporation pipe circling in the cooling device, and then sent to the warehouse for cooling. The advantages of air cooling are rapid cooling, uniform temperature in the warehouse, and can bring harmful gases such as carbon oxide out of the warehouse during storage.Babrook,Frequently check and acknowledge whether the voltage of the power supply meets the requirements, and the voltage should be V & plusmn; % (phase line). When the fresh-keeping warehouse equipment is not used for a long time, the main power supply of the fresh-keeping warehouse shall be cut off, and it shall be ensured that the fresh-keeping warehouse equipment is not affected by moisture, dust and other substances. The condenser on the refrigeration unit is simply contaminated, so as to cool the refrigerant, and then input the refrigerant into the box or building of the refrigeration equipment to cool the air according to the heat exchanger. This kind of refrigeration has slow cooling speed, large total heat conduction temperature difference and complex system software, so it can only be used in less places,BabrookInstallation and construction price of cold storage, such as brine ice making and cold storage with constant temperature requirements.Vijayawada,Precautions for purchase and shipment when using the medical cold storage project, the speed must be strictly guaranteed during the purchase and shipment of products. If the temperature of the medical cold storage is about degrees, the opening time must be strictly within minutes. If the temperature of the medical cold storage is left and right degrees, the opening time can not be too high, strictly within minutes.Watertight polyurethane rigid foam has low water absorption, and the obturator rate is more than %. It is a dense microporous foam material and state of foam pores. It is not connected with each other, which is more dense than the surface of the air,BabrookCold storage design quotation, and is not easy to permeate. It is an hydrophobic material.General quick-frozen warehouses are mostly cooled by refrigeration mechanism with low gasification temperature (ammonia or Freon)


BabrookProfessional installation cold storage installationDetailed interpretation



The spacing of pull rivets at inner and outer corners is mm and mm respectively; After the polystyrene library is installed, the wall panel joints shall be evenly sealed and decorated with silicone sealant.After the installation of the controlled atmosphere storage, another important finishing work is to purge the whole system. Compressed air will clean out the impurities remaining in the controlled atmosphere storage, which plays a key role in the use of the controlled atmosphere storage.It is equipped with temperature compensation to automatically adjust the water temperature. The water temperature of ultrasonic atomization is - degrees. If our humidifier is connected with the warehouse, there is no temperature compensation, even in the work, the water temperature is lowScheme customization,The factors affecting the installation cost of cold storage are as follows: cold storage construction: the site selection shall comply with laws and regulations and meet the relevant requirements for food hygiene and. And pay attention to protecting the environment and ecological balance. In addition, it shall be conducive to production, so that no other adhesive materials are needed. When polyurethane is used as a cold storage project, rigid polyurethane foam is formed between the panels of the storehouse panel, and then solidified and pressed to form a multi shape storeboard, because the metal plate can roll out different waveforms, so that the overall rigidity is stronger and the bearing capacity is higher. Polyurethane filler board can meet the firmness and physical requirements of exterior wall and can be used in various cold storage projects. It is technically feasible and cost-effective. Yuanbao refrigeration believes that polyurethane is one of the new cold storage materials with great development prospects in the future. The thermal insulation materials of cold storage engineering should not only have good thermal insulation performance, but also be economical, applicable and environmental friendly. To ensure the smooth progress of our cold storage project, we should not only inquire about the raw materials of the cold storage, but also the types of cold storage. The common cold storage plates mainly include the following types, namely stainless steel plate, color zinc steel plate, salted steel plate, embossed aluminum plate and mm galvanized standard floor plate.When opening and drilling is required for the top warehouse plate or wall plate, the internal and external setting out and positioning shall be carried out according to the drawing design requirements, and the opening and drilling shall be carried out after review; The inlet hole, liquid inlet hole, return hole, water supply hole and drainage hole shall be opened with a hole opener. Construction treatment shall be carried out in time after opening and drilling, and the orifice shall be closed with foaming material or sealant to prevent air leakage and cold running; The door, vent and delivery port shall be decorated with wrapped edges and fixed with pull rivets, and locate it when it meets the vertical angle. Put the beautiful plate in a conspicuous place. When installing it on the side of the evaporator,BabrookRefrigerated drugs, make the drainage pipe in advance and make U-bend and silica gel outside the storage.How many?, good permeability to water vaporWatertight polyurethane rigid foam has low water absorption, and state of foam pores. It is not connected with each other, and the obturator rate is more than %. It is a dense microporous foam material, which is more dense than the surface of the air, and is not easy to permeate. It is an hydrophobic material.As the hub of the refrigeration core, the refrigerant changes from no pressure to high pressure and low pressure to a proportional pressure and low pressure. This high and low pressure can achieve the principle of refrigeration under the action of other parts.The type of cold storage to be built in the type of cold storage should be determined according to the type of circulating goods. For example, the cold storage that only circulates vegetables can only build a fresh-keeping cold storage, while the cold storage with refrigeration + freezing will be built if there are many types of circulating goods and great difference in storage temperature. As for the size of the cold storage, it should be determined according to the type, quantity, frequency, cycle, whether to use shelf stacking and so on. For example, for fruits and vegetables packed in cartons, and the size of cold storage construction can be estimated in combination with the storage capacity rate of about .-..Babrook,We must often use insulation board in our life. It's just the structure of the refrigerator, but the refrigerator, as a in the home still has some use environment. In the market or marine transportation, the environment of cold storage insulation board is not so optimistic. Professional cold storage installation, cold storage installation, cold storage construction, fruit preservation cold storage, medical cold storage quality assurance. During the preferential activities, new and old customers are welcome to consult. The environmental differences inside and outside the cold storage insulation board are very large, because a large number of items need to be insulated, so the temperature in the cold storage is strict. In such cases, the cold storage insulation board will have relevant problems, Let's understand that the water vapor pressure outside the plate warehouse of the lower cold storage is higher than that inside the warehouse, and the penetration of the envelope is carried out from outside to inside all year round. R gas in polyurethane is replaced by air and water vapor to damp polyurethane. Over time, moisture becomes more and more serious, and even water vapor condensation occurs, resulting in low thermal conductivity and reduced thermal resistance. In order to avoid and delay polyurethane moisture and prolong the service life of the insulation layer, it is effective to seal the hot side of the insulation layer, that is, to form a vapor barrier layer.When installing the polyurethane insulation board, the adhesion between the panel of the polyurethane insulation board and the thermal insulation material is short and often high.Operating the unit: regularly observe the oil level and oil return of the compressor and the cleanliness of the oil. If the oil is dirty or the oil level drops, it shall be solved in time to avoid adverse effects.

comment list
©2009-2024Industrial Microblog  Sitemap